SolarWinds · Solutions Engineering · APJ
Size a full-stack SolarWinds Observability SaaS subscription across all modules — Network, Infrastructure, Application (APM), Database, Digital Experience (Synthetics & RUM), and Logs — using the à-la-carte, entity/consumption-based model. This calculator returns licensable quantities only (no pricing). Because the SaaS backend is hosted by SolarWinds, the only customer-side "hardware" to size is the collectors and agents that ship telemetry to the cloud.
Monitoring scope (entities)
Network & Infrastructure Observability
Routers, switches, firewalls (1:1).
10 share 1 entitlement.
Agent or collector (1:1).
VMware/Hyper-V/Nutanix host (1:1).
3 share 1 entitlement.
AWS/Azure services, 3:1.
10 share 1 entitlement.
1:1.
Drives dedicated flow collector sizing (≤40,000 FPS each).
Applications & Databases
Per active service, any # instances.
Per active instance.
Digital Experience — Synthetic Uptime
Distinct targets to monitor.
e.g. HTTP(S), TCP, ICMP, DNS.
SolarWinds cloud test locations.
Agent-based probes hosted inside the customer network for internal endpoints.
Digital Experience — Transactions & RUM
Scripted multi-step journeys. 2 / bundle (5 checks each).
Bundles of 100,000 pageviews.
Logs
Priced per GB/day; org ceiling ≈ 200 GB/hr.
Licensing
Licensable quantities for active modules only. Confirm all quantities in CPQ.
| Module | Unit of measure | Quantity |
|---|
Customer-side sizing
Documented minimum collector spec
| Component | Qty | CPU | RAM | Storage |
|---|
Recommended spec + HA / redundancy
| Component | Qty | CPU | RAM | Storage |
|---|
Reference
| Module | Entity / unit | Counts as |
|---|---|---|
| Network | Network device (router/switch/firewall) | 1:1 |
| Network | Wireless access point | 10:1 |
| Infrastructure | Host / server (agent or collector) | 1:1 |
| Infrastructure | Hypervisor / virtual host | 1:1 |
| Infrastructure | Standalone VM | 3:1 |
| Infrastructure | Cloud service (AWS/Azure, non-host) | 3:1 |
| Infrastructure | Kubernetes container | 10:1 |
| Infrastructure | Storage array | 1:1 |
| Infrastructure | ICMP-only status node | Free |
| APM | Application service (any # instances) | Per service |
| Database | Database instance | Per instance |
| DEM — Synthetic Uptime | Uptime check = endpoint × location × protocol | 10 uptime checks / bundle |
| DEM — Synthetic Transactions | Scripted transaction (5 checks each) | 2 transactions / bundle |
| DEM — RUM | Pageviews | Per 100,000 / month |
| Logs | Log ingestion | Per GB (monthly plan) |
Indicative SE quantity-sizing estimate for SolarWinds Observability SaaS. Entity weighting, module tiering, and collector counts must be validated in CPQ and against current SolarWinds Observability SaaS system-requirements and subscription documentation before quoting.
SolarWinds · Solutions Engineering · APJ
Size the SolarWinds Observability Self-Hosted (OSH) Essentials or Advanced tier from monitored node capacity, then derive minimum and recommended self-hosted hardware. Both tiers use simple node-based licensing and scale through Standard and Enterprise editions. Poller sizing follows the 2026 scalability guide — per-poller capacity is protocol-dependent, not a flat element count.
Licensing inputs
Essentials: NPM, SAM, LA, IPAM, UDT, VNQM & Cloud. Advanced adds NTA, NCM, VMAN, SCM, anomaly-based alerting & the security vulnerability dashboard.
Servers, network devices, wireless controllers, autonomous APs, and any node with monitoring beyond ICMP status. Exclude ICMP-only status nodes (free).
Standard scales up to 1,500 nodes. Enterprise is required beyond 1,500 nodes and whenever Additional Polling Engines (APEs) are needed.
Self-Hosted (OSH) polling workload
Sets per-poller element capacity: SNMPv2 100k · SNMPv3 72k · WMI/WinRM 20k (max 2,000 nodes), at 16 cores.
Interfaces, volumes, apps, component monitors per node. Typical 8–12.
40k / APE.
1,000 / poller.
50k FPS / poller. Requires Advanced (NTA).
25–50 / web server.
Reference
Selected tier highlighted. Advanced includes everything in Essentials plus the additional capabilities below.
| Capability | Essentials | Advanced |
|---|
Additional Polling Engines (APEs), Enterprise Operations Console (EOC), and lab licenses require the Enterprise edition of either tier. High Availability is available as an add-on on Standard.
Reference
Matching tier highlighted. Standard up to 1,500 nodes; Enterprise from 500 and required beyond 1,500.
| Edition | Available node tiers |
|---|---|
| Standard | |
| Enterprise |
Hardware sizing
| Component | Qty | CPU | RAM | Storage |
|---|
| Component | Qty | CPU | RAM | Storage |
|---|
Reference
| Dimension | Per polling engine | Per instance |
|---|---|---|
| Elements — SNMPv2 | 100,000 (16 cores; +7,500/core → max 150,000) | 1,000,000 elements · 100 APEs |
| Elements — SNMPv3 | 72,000 (16 cores; +5,000/core → max 100,000) | |
| Elements — WMI/WinRM | 20,000 (max 2,000 nodes; +2,000/core → 30,000) | |
| SAM component monitors | 40,000 (APE) · ~10,000 (main) | 550,000 |
| NetFlow (NTA) — Advanced | 50,000 flows/sec | 300,000 flows/sec |
| SolarWinds agents | 1,000 (−10 per remote collector) | — |
| UDT ports | 100,000 | 500,000 |
| VMAN VMs — Advanced | 10,000 (per APE) | — |
| Web console users | 25–50 per web server | 50–100 (main) |
Indicative SE sizing estimate for OSH Essentials and Advanced. Licensing, module coverage, protocol mix and final hardware must be validated in CPQ and against the customer's live license report and current 2026 system-requirements / scalability documentation before quoting.
SolarWinds · Solutions Engineering · APJ
Size the SolarWinds Observability Self-Hosted (OSH) Premier tier from monitored capacity, then derive minimum and recommended hardware for the self-hosted platform and the SaaS side (network collectors and per-host agents). Poller sizing follows the 2026 scalability guide — per-poller capacity is protocol-dependent, not a flat element count.
Licensing inputs
Servers, network devices, wireless controllers, autonomous APs, paid ICMP nodes. Exclude ICMP-only status nodes (free).
3 share 1 node.
10 share 1 node.
10 share 1 node.
Included components (Tier 2 · no node impact in 2026.2)
Self-Hosted (OSH) polling workload
Sets per-poller element capacity: SNMPv2 100k · SNMPv3 72k · WMI/WinRM 20k (max 2,000 nodes), at 16 cores.
Interfaces, volumes, apps, component monitors per node. Typical 8–12.
40k / APE.
1,000 / poller.
50k FPS / poller.
25–50 / web server.
SaaS monitoring scope
Agentless via Network Collector — up to 7,000 standard devices each.
Per-host agent.
Via collector.
≤40,000 flows/sec per collector.
Reference
Matching tier highlighted. Standard up to 1,500 nodes; Enterprise from 500 and required beyond 1,500.
| Edition | Available node tiers |
|---|---|
| Standard | |
| Enterprise |
Hardware sizing
| Component | Qty | CPU | RAM | Storage |
|---|
| Component | Qty | CPU | RAM | Storage |
|---|
| Component | Qty | CPU | RAM | Storage |
|---|
| Component | Qty | CPU | RAM | Storage |
|---|
Reference
| Dimension | Per polling engine | Per instance |
|---|---|---|
| Elements — SNMPv2 | 100,000 (16 cores; +7,500/core → max 150,000) | 1,000,000 elements · 100 APEs |
| Elements — SNMPv3 | 72,000 (16 cores; +5,000/core → max 100,000) | |
| Elements — WMI/WinRM | 20,000 (max 2,000 nodes; +2,000/core → 30,000) | |
| SAM component monitors | 40,000 (APE) · ~10,000 (main) | 550,000 |
| NetFlow (NTA) | 50,000 flows/sec | 300,000 flows/sec |
| SolarWinds agents | 1,000 (−10 per remote collector) | — |
| SRM LUNs | 40,000 | 160,000 |
| UDT ports | 100,000 | 500,000 |
| VMAN VMs | 10,000 (per APE) | — |
| Web console users | 25–50 per web server | 50–100 (main) |
| SaaS Network Collector | 7,000 standard devices · 40,000 flows/sec | deploy multiple |
Indicative SE sizing estimate. Pricing, value-based licensing weights, protocol mix, and final hardware must be validated in CPQ and against the customer's live license report and current 2026 system-requirements / scalability documentation before quoting.
SolarWinds Sizing · by Westcon ID Team
Reach out to the Westcon team for licensing validation, CPQ quotes, and sizing reviews.